Cat 5 25 Pair Riser Rated Cable
When you need to run multiple pairs or Cat 5 cable from floor to floor or equipment room to equipment room. Riser rated cable (Non-Plenum) has multiple pairs that you can split out for each one of your data or voice runs, depending on your particular system needs.  Of course you should keep in mind the maximum run lengths that is recommended for category 5 cable runs. You can also use this cable for voice cable runs. Remember to follow recommended building codes and electrical codes when running cable and knowing your requirements before you install any cable. 

PART NUMBER: SCPCAT5-25pr
Available
in 1000 Ft. bulk length only.

Reel Weight Approx. 98lbs. 
Ships from the East Coast.
Color  : Gray

DESCRIPTION: 24 AWG / 25 Pair CATEGORY 5 DATA CABLE
Com-Lan 5
RATING: UL DUAL LISTED CMR/MPR and C(UL) LISTED CMG-FT4
CERTIFICATIONS: UL Type CMR
ETL Verified Category 5.

Construction Parameters:

INFORMATION DIAMETER*
Conductors: Solid Copper 0.020
Dielectric: Solid Polyethylene  0.037
Pair lays: Each pair has different lay length for cross-talk prevention -
Ripcord: Polyester  -
Jacket: PVC Gray 0.480
Weight Approx 95 lbs.

Electrical Properties:   

DC Resistance Max.(ohms/1000’ @ 20 o C): 28.6
DC Resistance Unbalance Max.(%): 5
Characteristic Impedance (ohms): 1-100 MHz  85-115
Capacitance Max. (pF/ft): 20
Velocity of Propagation* (%): 66
Pair-to-Ground Cap. Unbal. Max.(pF/100m): 330
Worst-Pair Near-End 772 kHz 64**
Crosstalk Min. (dB): 1.0 MHz
4.0 MHz
8.0 MHz
10.0 MHz
16.0 MHz
20.0 MHz
25.0 MHz
31.25 MHz
62.5 MHz
100.0 MHz
62**
53**
48**
47**
44**
42**
41**
39**
35**
32**
The (**) values are for information only. The min.
NEXT coupling loss for anypair combination at room temp
is to be greater than the value determined
using the formula
NEXT(FMhz)³NEXT(0.772)-15log10(FMhz/0.772) for all freq.
in the range of 772 Mhz-100 MHz for a min. length of 100 m.
Attenuation Max.(db/100m):  256 
512 
772 
1.0 
4.0 
8.0 
10.0 
16.0 
20.0 
25.0 
31.25 
62.5 
100.0 
kHz
kHz
kHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
1.1
1.5
1.8
2.0
4.1
5.8
6.5
8.2
9.3
10.4
11.7
17.0
22.0
Structural Return  1.0- 20.0  MHz 23
Loss Min. (dB): 25.0
31.25 
62.5 
100.0 
MHz
MHz
MHz
MHz
22**
21**
18**
16**
The (**) values are for information only. The SRL is to be determined using
the formula SRLF ³ SRL20 - 10log10(F/20)

Miscellaneous Information

Pair Colors:  W/BL with BL, W/O with O, W/GR with GR, W/BR with BR
Jacket Color:  Typical is Gray (others available)
Flame rating: UL-1666 Riser Flame Test
CSA FT4 Vertical Flame Test
Applicable NEC Article: 725 & 800
Applicable TIA/EIA: 568-A
Approximate Weight
(lb/1000 ft):
95